What is a Sentinel Kinetic?

Sentinel Kinetic is Vent-Axia’s range of MVHR units, and one of the most common systems we see in new-build flats and family homes. It extracts stale, moist air from kitchens and bathrooms, recovers heat from it, and supplies filtered fresh air to the rest of the home.

We service and repair every model, including the Kinetic B, BH, FH, Plus B and High Flow. Your model is on the label on the unit, and it tells you which filters you need.

Vent-Axia MVHR unit in a utility cupboard

Sentinel Kinetic fault codes explained

When a fault has stopped the unit for more than 3 minutes, the display shows a fault code. If there’s more than one fault, the codes are added together.

01: Supply fan not running

The fan that brings fresh air in has stopped. Usually a failed motor or an electrical fault.

02: Extract fan not running

The fan that removes moist air has stopped. Expect condensation until it’s fixed.

03: Both fans not running

01 and 02 added together. The unit isn’t ventilating at all.

08: Supply temperature sensor

The sensor on the incoming air (T1) is faulty.

16: Extract temperature sensor

The sensor on the outgoing air (T2) is faulty.

32: Wired remote failure

The wired remote control isn’t communicating with the unit.

Other messages on the display

Check Filter

The filter service interval is up. Clean or replace the filters, then reset the reminder.

Summer Bypass On

Fresh air is bypassing the heat exchanger to help keep your home cool. Normal, not a fault.

Antifrost Active

The unit is cutting supply airflow in freezing weather to protect itself. Normal in very cold spells.

Room Too Cold

Below 5°C the fans stop. The unit restarts every hour to check the temperature.

Source: Vent-Axia Sentinel Kinetic installation and commissioning manual. View the manual (PDF)

Vent-Axia’s recommended maintenance

What Vent-Axia’s own documents recommend, and what we cover at every service.

Buy Vent-Axia filters online

Only need filters? Order the right set and we’ll post it to you.

Replacement MVHR filters

Vent-Axia FH filter set

Replacement filter set, £20.

Vent-Axia BH filter set

Replacement filter set, £16.

Not sure which filters?

Send us the model from the label on your unit and we’ll confirm the right set.

Vent-Axia service and repair prices

Same fixed prices for every make, confirmed before we arrive.

Cleaned MVHR heat exchanger after a full service
Most booked

Full MVHR Service

£149

Deep clean, new filters, airflow tested and rebalanced in every room, photo report. 90–120 min.

Engineer checking an MVHR control panel

Fault Finding Visit

£80

Full diagnosis, duct and airflow checks, PCB testing, written repair quote.

MVHR circuit board being repaired

Repairs

From £150

Fans, circuit boards, ducts and leaks. Parts quoted before work starts.

New Nuaire MRXBOX MVHR unit installed

Unit Replacement

From £1,290

Supply and fit, controls set up, airflow set, hand-over demonstration.

Trusted by homeowners across Bristol & Bath

What customers say after a Ventfix visit.

Patricia Paynter
“Excellent service. I was given advice and information about my vent and the issues it can cause in my flat if it’s not working. My vent was repaired and has been working really well ever since!”
Natalie
“Detailed and thorough inspection where everything was explained fully. The engineer was polite and very helpful. I wouldn’t hesitate in using again.”
Chris M.
“The engineer arrived within the allotted time, was polite, friendly and efficient. Spent just under an hour servicing the unit, ducts and changing filters.”
Steve Mackay
“Engineer was on time and very friendly. Answered all my questions on the unit and did a quick and thorough inspection. Very satisfied.”
Stephen Viiney
“The engineer took time and care to ensure our Vent-Axia Sentinel MVHR is in good shape. He also cleaned all the outlets and checked the flow rates.”

We service all makes and models, including

Vent-Axia Sentinel questions

On a Sentinel Kinetic, 01 means the supply fan isn’t running and 02 means the extract fan isn’t running. The unit has switched itself off because of the fault, so book a fault-finding visit.

Codes are added together when there’s more than one fault, so 03 means both fans aren’t running (01 + 02).

Your filters are due. Clean or replace them, then reset the reminder using the button combination in your unit’s manual. We sell FH and BH filter sets, or can fit them at a service.

The room temperature has dropped below 5°C, so the unit has stopped its fans. It restarts every hour to check the temperature.

Vent-Axia recommends an annual professional service, with filters changed every 6 to 12 months depending on whether you live in an urban, suburban or rural area.

Yes. We sell FH and BH filter sets online and can post them to you, or fit them as part of a service.

Ventfix is an independent MVHR specialist and is not affiliated with or endorsed by Vent-Axia. Brand names are trademarks of their respective owners. Full manuals are available from Vent-Axia.

Book your Vent-Axia service

Fixed price, the right filters, photo report after every visit.

Request a Free Quote

Fill out the form below, and we will be in touch shortly.

Contact Information
What service are you enquiring about?